LV Aerial Bundled Conductor (ABC) Cables
Nominal Voltage:
0.6/1kV
Standard:
IEC 60502
Category:
Aerial Bundled Cable
E-mail:
Description
AERIAL BUNDLED CABLES(ABC)
LV Aerial Bundled Conductor (ABC) Cables
Application
Aerial Bundle Cable (ABC cable) is a very innovat ive concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system. It provides higher level of safety and reliability , lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.
Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole t o pole) or st reet lighting. This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.
Standard
Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/ NZS 3560-1 standards
Construction
Conductor: Aluminium conductor, round stranded compressed (RM).
insulation: XPLE compound, UV-resistant.
Core identification: 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm² and a minimum of 16 ribs for cores above 50 mm². In the case of five core bundles the surface of the protective core should be smooth.
Electrical Properties
Rated Voltage |
0.6/1kV |
Test Voltage |
4 Veff kV |
minimum laying Temperature |
-20°C |
operating Temperature |
-40°C~ +90°C |
maximum Short-circuit Temperature |
250°C |
maximum Conductor Temperature |
80°C |
minimum Bending radius |
18×OD |
Construction Parameter
- BS 7870
Number of Cores xNominal Cross Section |
Overall Diameter |
Weight |
Maximum Conductor Resistance |
Minimum Breaking Load |
Current Rating |
No.×mm² |
mm |
Kg/Km |
Ω/Km |
KN |
A |
1x16 RM |
8,0 |
74 |
1,910 |
2,5 |
72 |
1x25 RM |
9,0 |
106 |
1,200 |
4,0 |
107 |
1x35 RM |
10,5 |
138 |
0,868 |
5,5 |
132 |
1x50 RM |
11,8 |
182 |
0,641 |
8,0 |
165 |
1x70 RM |
13,0 |
252 |
0,443 |
10,7 |
205 |
1x95 RM |
15,4 |
333 |
0,320 |
13,7 |
240 |
1x120 RM |
17,0 |
408 |
0,253 |
18,6 |
290 |
1x150 RM |
19,0 |
502 |
0,206 |
23,2 |
334 |
1x185 RM |
21,0 |
611 |
0,164 |
28,7 |
389 |
1x240 RM |
24,0 |
801 |
0,125 |
37,2 |
467 |
2x16 RM |
15,6 |
147 |
1,910 |
2,5 |
72 |
2x25 RM |
18,0 |
208 |
1,200 |
4,0 |
107 |
2x35 RM |
20,0 |
277 |
0,868 |
5,5 |
132 |
2x50 RM |
23,5 |
361 |
0,641 |
8,0 |
165 |
Number of Cores xNominal Cross Section |
Overall Diameter |
Weight |
Maximum Conductor Resistance |
Minimum Breaking Load |
Current Rating |
No.×mm² |
mm |
Kg/Km |
Ω/Km |
KN |
A |
2x70 RM |
25,4 |
505 |
0,443 |
10,7 |
205 |
2x95 RM |
30,3 |
666 |
0,320 |
13,7 |
240 |
2x150 RM |
38,0 |
1004 |
0,206 |
23,2 |
334 |
4x16 RM |
18,8 |
286 |
1,910 |
2,5 |
72 |
4x25 RM |
21,2 |
430 |
1,200 |
4,0 |
107 |
4x35 RM |
24,1 |
553 |
0,868 |
5,5 |
132 |
4x50 RM |
27,8 |
746 |
0,641 |
8,0 |
165 |
4x70 RM |
31,8 |
1.009 |
0,443 |
10,7 |
205 |
4x95 RM |
37,8 |
1.332 |
0,320 |
13,7 |
240 |
4x120 RM |
54,4 |
1.632 |
0,253 |
18,6 |
290 |
4x50 + 1x25 RM |
319 |
814 |
0,641/1,200 |
8,0/4,0 |
165/107 |
4x50 + 1x35 RM |
319 |
845 |
0,641/0,868 |
8,5/5,5 |
165/132 |
4x70 + 1x25 RM |
360 |
1105 |
0,443/1,200 |
10,7/4,0 |
205/107 |
4x70 + 2x25 RM |
400 |
1217 |
0,443/1,200 |
10,7/4,0 |
205/107 |
4x95 + 1x25 RM |
418 |
1438 |
0,320/1,200 |
13,7/4,0 |
240/107 |
4x95 + 2x25 RM |
420 |
1544 |
0,320/1,200 |
13,7/4,0 |
240/107 |
4x120 + 1x25 RM |
590 |
2050 |
0,253/1,200 |
18,6/4,0 |
290/107 |
Other cross-sections can be offered upon request.
TnB Specification(iEC 60502)
Number of Cores xNominal Cross Section |
Overall Diameter |
Weight |
Maximum Conductor Resistance |
Minimum Breaking Load |
Current Rating |
No.×mm² |
mm |
Kg/Km |
Ω/Km |
KN |
A |
1x16+1x25 RM |
15.3 |
160 |
1,910 |
2,5 |
72 |
Number of Cores xNominal Cross Section |
Overall Diameter |
Weight |
Maximum Conductor Resistance |
Minimum Breaking Load |
Current Rating |
No.×mm² |
mm |
Kg/Km |
Ω/Km |
KN |
A |
3x16+1x25 RM |
19.0 |
290 |
1,200 |
4,0 |
107 |
3x25+1x25 RM |
23.2 |
400 |
0,868 |
5,5 |
132 |
3x35+1x25 RM |
25.6 |
500 |
0,641 |
8,0 |
165 |
3x50+1x35 RM |
30.0 |
680 |
0,443 |
10,7 |
205 |
3x70+1x50 RM |
34.9 |
920 |
0,320 |
13,7 |
240 |
3x95+1x70 RM |
40.6 |
1270 |
0,253 |
18,6 |
290 |
3x120+1x70 RM |
44.1 |
1510 |
0,206 |
23,2 |
334 |
3x150+1x95 RM |
49.2 |
1870 |
0,164 |
28,7 |
389 |
3x185+1x120 RM |
54.9 |
2340 |
0,125 |
37,2 |
467 |
3x25+1x25+1x16 RM |
23.2 |
470 |
1,910 |
2,5 |
72 |
3x35+1x25+1x16 RM |
25.6 |
560 |
1,200 |
4,0 |
107 |
3x50+1x35+1x16 RM |
30.0 |
740 |
0,868 |
5,5 |
132 |
3x70+1x50+1x16 RM |
34.9 |
980 |
0,641 |
8,0 |
165 |
3x95+1x70+1x16 RM |
40.6 |
1330 |
0,443 |
10,7 |
205 |
3x120+1x70+1x16 RM |
44.1 |
1580 |
0,320 |
13,7 |
240 |
3x150+1x95+1x16 RM |
49.2 |
1940 |
0,206 |
23,2 |
334 |
3x185+1x120+1x16 RM |
54.9 |
2410 |
1,910 |
2,5 |
72 |
Other cross-sections can be offered upon request.